Math o Dalu: | T/T,Paypal,Money Gram,Western Union |
---|---|
Incoterm: | FOB,CIF |
Min. Gorchymyn: | 1 Set/Sets |
Model Rhif: HLG-150H
Brand: Meentwell
Pecynnu: Bocsiwyd
Cynhyrchiant: 20000pcs per month
Cludiant: Ocean,Land,Air
Lle Tarddiad: Guangdong, China
Gallu Cyflenwi: 5000pcs per month
Porthladd: Shenzhen,Guangzhou,Hongkong
Math o Dalu: T/T,Paypal,Money Gram,Western Union
Incoterm: FOB,CIF
HLG-150H Cyflenwad pŵer LED gwrth-ddŵr cymedrol
Disgrifiad o gynhyrchion
Cyflenwad pŵer newid allbwn sengl 150W gwrth -ddŵr 150W , Y model canlynol a ddefnyddir yn helaeth gyda lampau LED ` s iseeled , HLG -150 H -12 , HLG -150 H -1 5 , HLG -150 H -24, ac ati Rhywfaint o fodel arall ar gyfer lampau arbennig gyda foltedd mewnbwn gwahanol.
HLG -150 H -12 BLANK: IP67 Graddiwyd. Cebl ar gyfer cysylltiad I/O.
HLG -150 H -12A: Graddiwyd IP65. Gellir addasu foltedd allbwn a lefel gyfredol gyson trwy potentiometer mewnol.
HLG -150 H -12B: IP67 Graddiwyd. Y lefel gyfredol gyson y gellir ei haddasu trwy gebl allbwn gyda signal neu wrthwynebiad 1 ~ 10VDC neu PWM.
HLG -150 H -12D (Opsiwn): IP67 Graddiwyd. Swyddogaeth pylu amserydd, cyswllt yn golygu'n dda am fanylion.
Model |
HLG-150H-12 |
HLG-150H-15 |
HLG-150H-24 |
|
Output |
DC VOLTAGE |
12V |
15V |
24V |
CURRENT ADJ. RANGE |
Can be adjusted by internal potentiometer A type only |
|||
7.5-12.5A |
6-10A |
3.8-6.3A |
||
RATED POWER |
150W |
150W |
151.2W |
|
VOLTAGE ADJ. RANGE |
10.8-13.5V |
13.5-17V |
22-27V |
|
Input |
Voltage Range |
90-264VAC 127-370V DC |
||
Frequency Range |
47-63Hz |
|||
POWER FACTOR |
PF>0.98/115VAC, PF>0.95/230VAC, at full load (Please refer to "Power Factor Characteristic" curve) |
|||
Efficiency(Typ.)(230Vac) |
92% |
92.5% |
93.5% |
|
AC CURRENT (Typ.) |
1.7A / 115VAC 0.75A / 230VAC |
|||
INRUSH CURRENT(Typ.) |
COLD START 75A/230VAC |
|||
LEAKAGE CURRENT |
<0.75mA / 240VAC |
|||
PROTECTION |
OVER LOAD |
95~ 108% |
||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||
SHORT CIRCUIT |
Constant current limiting, recovers automatically after fault condition is removed |
|||
OVER VOLTAGE |
14-17V |
18-21V |
28-34V |
|
Protection type :Shut down O/P voltage, re-power on to recover |
||||
OVER TEMPERATURE |
100 ℃ up or less10 ℃ (RTH2) |
|||
Protection type : Shut down and latch off o/p voltage, recovers automatically after temperature goes down |
||||
Environment |
WORKING TEMP. |
-40 ~ +70 ℃(Refer to output load derating curve) |
||
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
|||
SAFETY |
SAFETY STANDARDS |
UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1 |
||
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
|||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH |
|||
EMC EMISSION |
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3 |
|||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A |
|||
Others |
MTBF |
192.2K hrs min. MIL-HDBK-217F (25℃ ) |
||
DIMENSION |
228*68*38.8mm (L*W*H) |
|||
PACKING |
1.15Kg; 12pcs/14.8Kg/0.8CUFT |
|||
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details. 5. Type A only. 6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 9. Refer to warranty statement. |
1. Mae'r holl baramedrau na chrybwyllir yn arbennig yn cael eu mesur ar fewnbwn 230VAC, llwyth wedi'i raddio a 25 o'r tymheredd amgylchynol. Nodyn
2. Mae Ripple & Sŵn yn cael eu mesur ar 20MHz o led band trwy ddefnyddio gwifren bâr troellog 12 "wedi'i therfynu â chynhwysydd cyfochrog 0.1UF & 47UF.
3. Goddefgarwch: Yn cynnwys sefydlu goddefgarwch, rheoleiddio llinell a rheoleiddio llwyth.
4. Efallai y bydd angen derating o dan folteddau mewnbwn isel. Gwiriwch y nodweddion statig am fwy o fanylion.
5. Teipiwch A yn unig.
6. Diogelwch a Dylunio EMC Cyfeiriwch at EN60598-1, CNS15233, GB7000.1, FCC Rhan18.
7. Mae hyd yr amser sefydlu yn cael ei fesur ar y dechrau cyntaf. Gall troi ymlaen/oddi ar y cyflenwad pŵer arwain at gynnydd yn yr amser sefydlu.
8. Mae'r cyflenwad pŵer yn cael ei ystyried yn gydran a fydd yn cael ei weithredu mewn cyfuniad ag offer terfynol. Gan y bydd y perfformiad EMC yn cael ei effeithio gan y Gosodiad cyflawn, rhaid i'r gweithgynhyrchwyr offer terfynol ail-gymhwyso cyfarwyddeb EMC ar y gosodiad cyflawn eto.
9. Cyfeiriwch at Ddatganiad Gwarant.Categorïau Cynnyrch : Ategolion dan arweiniad > Cyflenwad pŵer gwrth -ddŵr cymedrol
Gwefan Symudol Mynegai. Map o'r Wefan
Tanysgrifio i'n Cylchlythyr:
Cael Diweddariadau, Gostyngiadau, Arbennig
Cynigion a Gwobrau Mawr!